How to set waterproofing and insulation
WhereFinishes tab
Steps
- Floor waterproofing: Liquid membrane, Penetrating or Sheet membrane; check the turn-up onto the walls (200 mm by default) and click on the room or drag out an area (for example, a shower).
- Wall waterproofing: the card, height from the floor, click near a wall or in the room.
- Sound and heat: at the top choose Floor, or Ceiling, then the material (mineral wool, Penoplex, ZIPS, Soundline, membrane, sheet under screed, cork) and the thickness. Floor and ceiling: click on the room. Walls: click near a wall, and the layer will be added to its type on that side, and the wall will become thicker.
What is important to know
- According to SP 29, cl. 7.2, waterproofing is turned up onto the walls to at least 200 mm, and in a shower to the full wetting height.
- A wet room without floor waterproofing produces a warning (SP 29, cl. 7.1).
- The bathroom floor must be 15–20 mm lower than the adjacent ones, or have a threshold up to 20 mm, or the whole floor must be waterproofed (SP 29, cl. 4.8).
- No consumption rate was found for penetrating waterproofing, and the materials list shows the note No data.