How to get the schedule, quantities and check
Wherethe Schedule and check card at the top of the panel
On the left of the window are the check settings:
- finish class per GOST R 72509-2026 (1–6; a click on the selected one clears the selection) and the class tolerances in groups;
- diameter of the underfloor heating pipe;
- Materials and works are in the estimate: the Open button leads to the estimate.
Tabs (they do not fit in a narrow window, and the strip scrolls with the mouse wheel, there is no scroll bar; the selected tab slides into the visible part by itself):
- Schedule shows room cards: ceiling, walls and partitions, wall bottom; each material has a sample and an area. Show on plan highlights the room.
| Floor legend | floor type, its rooms and share of area, section of the layer build-up (thicknesses are conventional) and layers from top to bottom; hovering over a layer highlights it in the section. |
|---|---|
| Colors | schedule of finishing materials per GOST 21.507-81, Fig. 1. Each material + type pair has a color number, the same as on the leader shelf on the wall elevations. In the row, enter the reference (RAL, NCS or catalog article number): it is saved in the project and goes into the schedule and the album. |
| Materials | filters by group and Check (no allowance, no plank length, no consumption data). A row shows: per project, allowance, Buy (for tiles and boards, pieces per layout), pack size and source of the number. |
| Works | as cards, with the materials of the work. |
| Remarks | checks per SP 29 and SP 71 with the Show on plan button. |
CSV exports the open tab; in the album and CSV the schedule follows form 1 of GOST 21.501.
What is important to know
- Consumption and allowance are taken from manufacturers' data sheets. Where there is no data sheet, the number is marked assumed. From a data sheet range, the limit at which the material will be enough is taken.
- The floor is calculated by the room area without columns and shafts; areas of a different covering are cut out of the room covering.
- Walls are calculated up to the room ceiling without windows and doors; the backsplash is cut out of the area under it.
- Not counted: reveals of doors with a leaf (they are covered by the frame and trim fillers), boxes and projections not drawn as walls, the area under built-in furniture. Window reveals are counted from the room side, from the wall edge to the frame.
- Set the underfloor heating pipe so that the check can compare the screed thickness above the pipe with the norm (SP 29, cl. 8.2).
- It is calculated for the renovation result (stage Result), like the estimate and the album.
- Finish tolerances are no longer regulated in SP 71 since 01.02.2026: they are in GOST R 72509-2026 and apply if included in the contract.