How to place radiators

WhereWater and heatingRadiators

Steps

  1. Mark out the rooms in the Plan: the room type (bedroom, kitchen, bathroom) sets the temperature and the ventilation rate.
  2. Above the tiles are the steps of the section. In the Heaters step, click Place: a radiator will be placed under each window of a room with heat loss, with its power taken from the calculation.
  3. You can also place a radiator manually: the Radiators or Convectors row. It snaps to the wall with its back.
  4. Under the radiator symbols there is a Show 3D models button with ready-made models. A model is placed by the same radiator: with a symbol on the plan, in the calculation and snapping to the wall, and in 3D the model itself is visible. Boiler models in the Boiler and chimney row work the same way.
  5. In the heater window, in the Heating and ventilation block, enter the power from the data sheet and the temperature head it is given at: 70 °C for a Russian data sheet (GOST), 50 °C for a European catalog. Under the field you can see how much is needed according to the calculation.

What is important to know

  • There are sectional, panel, cast-iron, tubular and vertical radiators, and convectors: floor, in-floor, electric. On the plan a radiator is drawn as a rectangle, a convector with a line inside, an in-floor one with a half filled in (GOST 21.205).
  • For an electric convector the power is set in the Power draw field, and no pipes are needed for it. A radiator placed in the Plan is also taken into account by the calculation.
  • The radiator leader: above the line the number of sections (for a panel radiator and a convector, the length, mm), below the line the power, kW (GOST 21.602, cl. 6.1.9 k). Section pitch: bimetal 80 mm, cast iron 93 mm, tubular 45 mm.
  • A radiator is also needed in a bathroom with a window: a water towel warmer does not replace it if the heat loss is noticeable (SP 30, cl. 9.8).