How they are shown on the plan

WhatSymbolSource
Cold water riserA circle marked В1System designations per GOST 21.205
Hot water riserA circle, Т3Same
Sewer riserA circle, К1Same
Heating riserA circle, Т1Same
Gas riserA circle, Г1Gas pipeline designation per GOST 21.609
Plumbing riser with no system specifiedA circle, СтThe riser mark on the drawing starts with these letters
Ventilation ductA rectangle with one diagonalGOST 21.201-2011, Table 11
ChimneyA rectangle with a diagonal, half of it along the diagonal filled in blackGOST 21.201-2011, Table 11
Ceiling beamAn outline in a dash-dot line with two dotsThis is how anything above the cutting plane is shown, GOST 21.501-2011, cl. 5.3.4
ColumnAn outline with hatchingLike a cut structure
RadiatorA rectangle with section ribsIts own symbol

What to keep in mind

  • For a large riser, the designation is inside the circle. For a thin riser, the circle is small, so the designation is placed next to it.
  • The riser's fill color is an editor hint: blue for cold water, red for hot water and heating, gray for sewer, yellow for gas. The standard has no colors.
  • The symbols for the radiator, water inlet, gas water heater, meter and ventilation outlet have not been checked against the images in the standards.
  • Plan objects are not pushed out of walls: a riser or a column can stand in a wall.